Set the function switch to the 'V ~ Auto' position
1.
Insert the black test lead into the COM terminal and the
2.
lead into the V terminal
3.
Tester will automatically select AC or DC voltage
4.
Connect the test leads in parallel to the circuit under test
5.
Read the voltage measurement on the LCD display
4.3

Low Z voltage

Notes:
Observe all safety precautions when working on live
voltages. Do not connect to circuits that exceed 600
VAC/DC when the meter is set to Low Z.
Low Z is used when there is a suspicion of a 'ghost' voltage. Ghost
voltages are present when non-powered wires are in close proximity
to wires powered by AC voltage. Capacitive coupling between wires
make it appear that non-powered wires are connected to a real source
of voltage.
The Low Z setting places a load on the circuit, which dissipates and
greatly reduces ghost voltage.
Set the function switch to the 'V ~ LowZ' position.
1.
Momentarily press the Mode button to select AC or DC voltage
2.
The AC ' ~' or DC '
Insert the black test lead into the COM terminal and the
3.
lead into the V terminal
4.
If measuring DC voltage, touch the red test lead to the positive
side of the circuit and the black test lead to the negative side of
the circuit
5.
Connect the test leads to the circuit under test
6.
Read the voltage on the LCD display
' symbol will appear on the LCD display
red
test
red
test