c. Do not obstruct the airflow around the inverter. Leave at least 10 centimeters clearance around
the inverter. Do not place items on or over the inverter while it's operating. When the inverter is
running too hot, it will shut down until a safe temperature level is reached to restart the inverter.
d. Never use the inverter at locations where there is gas or explosion danger, like for example
directly on top of batteries, or in the neighbourhood of volatile liquids.
e. Do not expose the inverter to dusty environments
2.2
Using the "Remote On/Off" function
This Alessi inverter offers the possibility to connect an external (remote-) on/off SPST switch (min.
60VDC/1A). The two wires of the external switch must be connected to the terminals blocks as
indicated below. Before connecting an external switch, the factory installed link wire must be
removed first. Make sure that when installing the remote switch, the battery is NOT connected yet!
1
AC
PRESENT
COMM.
PORT
ERROR/
OVERLOAD
POWER
ON
REMOTE
ON / OFF
AUTOMATIC
STANDBY
Remove factory
installed link
The main on/off switch on the inverter frontpanel always overrides the remote on/off switch. So in
order to use the remote switch, the main on/off switch must be in the ON or Automatic standby
(ASB) position. Maximum recommended length of the remote switch wires are 50 meters. Use
good and professional wiring for these connections to avoid easy wire damage. The recommended
2
wire gauge is 0.2mm
The Alessi-Serie
Pure Sine Wave Inverters
2
(AWG24) or greater.
AC
PRESENT
COMM.
PORT
ERROR/
OVERLOAD
POWER
ON
REMOTE
ON / OFF
AUTOMATIC
STANDBY
max. 50 meters
- 5 -
remote spst
switch