EN
existing wall switch can be retained and the
lamp that was being activated using the wall
switch can also be activated with a wireless
wall-mounted transmitter or a wireless re-
mote control of the Cuveo system. For install-
ation purposes, it is important to ensure
there is enough space to position the "mini"
wireless flush-mount switch behind the
former wall switch.
a.) Ensure that the devices are disconnected
and volt-free and follow the safety
instructions above.
b.) Release the cover of the existing wall switch,
which is to be supplemented with a wireless
capability, and remove it from the flush
mounted socket.
c.) Remove both cables (phase "L" and the
switched phase "L L") from the wall switch
and connect them to the two screw ter-
minals (4) of the wireless flush-mount
18
switch (see fig.).
d.) If the lines "L" and "L L" are swapped or if
instead of phase "L" the neutral conductor
"N" is switched on, it is possible that at a
later stage it will not be possible to program
the wireless flush-mount switch or that the
LED lamps will malfunction.
e.) Connect both cables (3) of the wireless flush-
mount switch to the previous switch contact
of the wall switch "S1" (see fig.).
f.) Insert the wireless flush-mount switch into
the flush-mount socket so that LED (1) and
button (2) face forward.
g.) Ensure during the installation that the but-
ton at the back of the casing is bare and
not accidentally activated.
h.) The button at the back of the casing allows
configuration for a wireless transmitter of the

Advertenties