Download Inhoudsopgave Inhoud Print deze pagina

Technical Data - VOLTCRAFT IR 1000-30D Gebruiksaanwijzing

Infrarood-thermometer
Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Technical Data

Operating voltage:
Response time:
Spectrum:
Emissivity
Contact measuring range:
Resolution:
IR measuring spot size:
Laser:
Operating temperature
Operating humidity:
Storage temperature:
Storage humidity:
Weight:
Dimensions:
Accuracy (at an ambient temperature of 23 - 25 °C, wihtout measurement inaccuracies due to the
sensor)
Temperature measuring range:
- 50 to 1,000 °C
1000 to 1,370 °C
Accuracy (at an ambient temperature of 23 - 25 °C, measuring distance in the focal point of the target
laser)
Temperature measuring range:
- 50 to 20 °C
20 to 500 °C
500 to 1000
9V block battery
150 ms
8 - 14 µm
Adjustable from 0.1 to 1.00
- 50 °C to 1,370 °C
0.1 °C /°F < 1000 °C/°F
1 °C /°F < 1000 °C/°F
IR 1000-30D
IR 1200-50D USB and IR 1600-50D
Power < 1 mW, laser class 2,
wave-length 630 - 690 nm
0 to 50 °C
10 - 90 % RH
-10 to 60 °C
10 - 80 % RH
approx. 330 g
220 x 52 x 138 mm
Contact temperature measurement (type K)
Accuracy
± 1.5 % of the measured value ± 3.5 °C ± 1,5 %
± 1.5 % of the measured value ± 2 °C ± 1,5 %
Infrared temperature measuring range IR 1000-30D
Accuracy
± 4 °C
± 1.5 % of the measured ± 0.5 % of the measured value or ± 0.5 °C
value ± 1.5 °C
± 2 %
Repeatability
Repeatability
± 1.5 °C
± 0.5 % of the measured value or ± 0.5 °C
30:1
50:1
29

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Ir 1200-50d usbIr 1600-50d usb10 09 1310 09 1410 09 16

Inhoudsopgave