LED STATUS
Logger status
Battery
switched on
---
switched off
---
normal
records data**
low
repeating time synchronisation
---
normal
records data without connection to
network
low
normal
records + transmits data
low
normal
records + memory is full
low
data import + records + transmits
---
normal
not paired
low
normal
pairing
low
resetting to factory settings / resetting
---
network
low battery (product cannot be
low
switched on)
*If the sampling rate is longer than one minute, the LED will flash every minute. Otherwise, the LED will flash
during each sampling.
**If the sampling rate is two minutes or longer, the red power LED flashes once every minute (provided that
battery capacity is normal and the product is connected to the network). During the minute the sampling
takes place, the green signal LED will additional flash once.
When the logger has been paired with the dongle and is ready to use, and you press the button
"CONNECT", the red power LED will flash once. This serves to check the operational readiness of
the logger.
TROUBLESHOOTING
Logger status
repeating time synchronisation
records data without connection to network
records + memory is full
battery low
DISPOSAL
a)
Product
Electronic devices are recyclable waste and must not be disposed of in the household waste!
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
Remove any inserted (rechargeable) batteries and dispose of them separately from the product.
b)
(Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/rechargeable
batteries. Disposing of them in the household waste is prohibited!
Contaminated (rechargeable) batteries are labelled with this symbol to indicate that disposal
in the domestic waste is forbidden. The designations for the heavy metals involved are: Cd =
Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the trash
icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our stores
or wherever (rechargeable) batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
Signal LED
Power LED
flashes once when
flashes once when
switching on
switching on
off
off
flashes*
off
flashes twice*
flashes every ten
shines
seconds
flashes*
flashes twice*
flashes twice*
flashes*
flashes (only data
transmission)
flashes twice*
flashes*
flashes three times*
flashes twice*
flashes continuously
flashes*
flashes every ten
seconds
shines
flashes twice every ten
seconds
flashes every ten
seconds
flashes six times within
one second
flashes twice every ten
seconds
flashes continuously for
off
five seconds
flashes continuously
flashes continuously
measure
•
Make sure the dongle is properly connected to
the computer.
•
Make sure the software is running.
•
Make sure that a network has been set up.
•
If required, close the menu item "Sensor
Administration".
•
Pair the product to the network. If this does not
work, reduce the distance to the dongle and try
again.
Insert a new battery.
TEcHNIcAL DATA
General
Operating voltage:
Range:
Transmission rate:
Internal memory:
Operating temperature:
Operating humidity:
Storage temperature:
Storage humidity:
Dimensions (W x H x D):
WDL-TH Temp/rH
Measuring range (temperature):
Measuring range (humidity):
Accuracy (temperature):
Accuracy (humidity):
Resolution:
Weight:
WDL-P Pressure
Measuring range:
Accuracy:
Resolution:
Weight:
WDL-k Temp Type k
Measuring range:
Accuracy:
Resolution:
Weight:
Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7
(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© copyright 2011 by Voltcraft®
3.6 V battery type ½ AA
30 m (line of sight)
250 kbps
512 kbits
-40 to +70 ºC
0 – 100 %
-10 to +50 ºC
10 – 85 %
28 x 24 x 141 mm
-40 to +70 ºC
0 – 100 %
±1.2 ºC (0 to +40 ºC)
±2.4 ºC (-40 to 0 ºC / +40 to +70 ºC)
±3 % (20 – 60 %)
±4 % (10 – 20 % / 60 – 90 %)
±5 % (0 – 10 % / 90 – 100 %)
0.1 % / 0.1 ºC
approx. 33 g
300 – 1100 mbar
±2.5 mbar (0 to +65 ºC / 700 – 1100 mbar)
±3 mbar (0 to +65 ºC / 300 – 700 mbar)
±4 mbar (-20 to 0 ºC / 300 – 1100 mbar)
0.01 mbar
approx. 33 g
-40 to +520 ºC
±(0.5 % rdg + 2.9 ºC) at +25 ºC (typical)
0.1 ºC
approx. 34 g