Rated voltage
Switching current
Power consumption
Battery type
Degree of protection
Class of protection
(dependent on correct assembly)
Permissible ambient temperature
Type of mounting
Problem
Drive is not functioning.
Drive is running in the
wrong direction.
Astro program is not
switching accurately.
70 - en
Technical data
230 V AC / 50 Hz
5 A/250 V AC at cos
2 VA
CR 2032
IP 20
II
0 to +55°C
Flush mounted Ø 58 mm, wall moun-
ted/surface mounted in appropriate
surface mounted housing
What to do if...?
Cause
Incorrect connection.
Incorrect connection.
Date is incorrect.
Incorrect city or incor-
rect degree of latitude/
longitude set.
Holiday function
switched on.
Astro shift is set.
=1
Remedy
Check connection.
Swap over wire
wire
on the power
supply unit.
Set correct date.
Set correct city or exact
degree of latitude/lon-
gitude.
Switch off holiday func-
tion.
Adjust Astro shift.
and