Download Print deze pagina

Becker Centronic TimeControl TC52 Montage- En Gebruiksaanwijzing pagina 50

Schakelklok voor lichtsensor

Advertenties

Beschikbare talen

Beschikbare talen

OFFSET
An additional switching time
is dependent on the PROG1 switching time
Example:
Astro time
: 20:00
Offset
: +60 min.
The roller shutter moves into the ventilation position at 20:00 and into the
lower end position at 21:00.
Jan.
Feb.
15:00
18:30
22:00
Winter time
Setting menu
SETTING
In the SETTING menu, you have the following options:
HOLIDAY
SUN (if the sensor is connected)
TWILIGHT (if the sensor is connected)
INTERMEDIATE POSITION
VENTILATION/TILT
PROG1 (END POS, INTERM POS, VENT/TILT)
PROG2 (END POS, INTERM POS, VENT/TILT)
TEST MODE (if a sensor is connected)
Language selection (ENGLISH)
ASTRO SHIFT
ASTRO SHIFT
City selection (LONDON)
LONGITUDE (Appears only with EXPERT MODE ON)
50 - en
can be programmed in the OFFSET menu. This
Mar.
Apr.
May
Jun.
Summer time
(max. +/- 240 min.).
Jul.
Aug.
Sep.
Oct.
Nov.
Dec.
PROG 1
PROG 2
Offset +60 min.
Winter time

Advertenties

loading