Download Inhoudsopgave Inhoud Print deze pagina

Humidistat Setting; Heating Function - eeese Martha Handleiding

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

UK
D) Humidistat Setting
Set the desired humidity in % by pressing Button D. We recommend a relative humidity
of between 40% and 60%. The appliance can be regulated from 40% to 75%. If the
humidity exceeds the desired setting, the appliance will turn itself off. The appliance will
not turn itself off if it has been set for continuous operation ("CO"). The desired value is
shown while you are making the selection. After a few seconds, the display automatically
switches to the current value.
40% - 45% - 50% - 55% - 60% - 65% - 70% - 75% - 80 % - CO
E) Heating Function
Martha is also HUMIDIFIER & AIR PURIFIER the perfect humidifier in winter when the air in-
side is often dry. Martha incorporates a new heat technology that heats water in the tank
to 65 °C and inactivates bacteria and virus in the water that evaporates into the room.
Press button E to select heating function. Lights ON; press again E, its icon light OFF.
Status 1: the unit is working at CO status.
If press heating button, the unit will automatically start to heat for 25 minutes without
any fan speed. After 25 minutes, the unit will automatically turn heating ON or OFF
subject to current indoor humidity.
Please refer to below working status under different indoor humidity conditions.
Current Indoor Humidity
20%RH~40%RH
40%RH~60%RH
>60%RH
Status 2: The humidity is under 40%RH~80%RH status.
If you press the heating button, the unit will automatically start to heat for 25 minutes
without any fan speed. After 25 minutes, the unit will keep working on middle level mois-
ture output with heating ON, till the indoor humidity reaches up to your setting level, the
unit will automatically stop working.
The unit can turn heating ON or OFF according to the environment temperature.
The unit can turn heating ON or OFF when lack of water.
62
MV-2514-09-2022 . eeese-aircare.com © All rights reserved by eeese air care ApS
Working status of the unit
working on high level moisture output +
heating ON.
working on middle level moisture output +
heating ON.
working on low level moisture output.