Troubleshooting
Battery DC-DC Converter Error Code
Code
Message
B632
DDC_Battery Over
Voltage
B633
DDC_Battery Over
Current
B634
DDC_Over Voltage
B635
DDC_Link Over
Current
B636
DDC_Over
Temperature
B367
DDC_BMS_Loss of
Communication
4
B638
DDC_INVERTER_Loss
of Communication
B639
OVP CB Open
B640
Reverse Polarity_PV
power charge DC
B641
Reverse Polarity_
Battery try to
precharege
y Firmware version, Error codes and Fault conditions on the lists can be accessed on the display.
And those can also be accessed from the server.
Description
Battery DC-DC Converter Over
Voltage
Battery DC-DC Converter Over
Current
DC-DC Over Voltage
DC-DC Link Over Current
DC-DC Converter Over
Temperature
DC-DC BMS Loss of
Communication
DC-DC INVERTER Loss of
Communication
Over Voltage Protection Curcuit
Breaker Open
Reverse Polarity PV power charge
DC
Reverse Polarity Battery try to
precharege
Solution
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Contact service center
Automatically restart after
detecting fault
Automatically restart after
detecting fault

Advertenties