16
Installation
Choice of location
Mounting Location
2
This product must not be installed or used at altitudes above 2 000 m.
y This product is designed to be installed
indoor use only. Do not install this product
outdoor.
y Install this product on the place where PV
cables, energy meter cables, grid cables and
battery cables are easily accessible.
y This product is designed to be installed on
the wall only. Do not install this product on
the ground.
y The mounting surface must be able to
support the weight of this product (34 kg).
y Do not install the product on the ceiling.
y Do not install the product widthwise or install
on a wall with lean more than 10 degrees.
y Do not install the product tilting forward.
y Install the product the connection side down.
y Appropriate operating temperature is from
0° C to 40° C.
y Do not install this product in the place
exposed to the direct sunlight.
y Install the product in a clean, cool room.