Twilight function
The twilight threshold can be adjusted between darkness (Position 1) to early
dusk. In Position 0 the twilight function is switched off (the indicator lamp
flashes yellow 8 times).
Light intensity below the twilight threshold → shading solution comes down.
The factory setting is that the twilight function is switched
off.
The shading solution does not automatically move up again
after it has come down due to the light falling below the twi-
light threshold.

Glass breakage function

If the window pane is shocked, the glass breakage sensor becomes active,
and drives the shading solution down to the lower limit position.
Briefly press the
age function is switched off. To switch it back on, press the
and hold it down. The indicator lamp changes from red to green. The glass
breakage function is now switched on. To switch it off, press the
again and hold it down. The indicator lamp changes from green to red. The
glass breakage function is now switched off.
The factory setting is for the glass breakage function to be
switched off.

TEST mode

This mode lets you test the functionality of the sensor. In TEST mode, the
shade function times are shortened from minutes to seconds. Hold the
manual/auto button pressed down until the indicator lamp flashes green twice.
The TEST mode is now active for 5 minutes.
Manual/auto button
The manual/auto button allows you to switch the automatic drive commands
(e.g. sun protection function, twilight function) on and off.
In manual mode the indicator lamp gives a short red flash after operation.
In automatic mode the indicator lamp gives a short green flash after operation.
Press the manual/auto button again to change over.