Function
The RolloTec
system and is installed together with
in a flush-mounting box in acc. with DIN 49073 (deep box recommended).
By replacing the attachment module, the user has the chioce between manual
operation, comfortable operation by radio remote control or fully automatic time-
controlled operation.
The RolloTec
with one of the following attachments of the louver-blind/shutter control system (with/
without sensor input):
12
®
insert without extension input is a component of the RolloTec
a RolloTec
®
clock timer attachment module
®
or a RolloTec
pushbutton
®
insert without extension input can only be used in conjunction
RolloTec
®
pushbutton
RolloTec
®
radio control pushbutton
RolloTec
®
memory pushbutton
RolloTec
®
clock timer attachment module Easy
®
RolloTec
clock timer attachment module
®
GB
The insert is equipped with 2 high-power relay contacts interlocked with each other.
Simultaneous activation of both running directions in the shutter motor with resulting
damage to the motor is therefore excluded (see figure).
Each insert can control 1 motor with limit switches and a rating up to 1000 W
maximum. Observe the instructions of the motor manufacturers.