INSTRUCTION MANUAL FOR DISHWASHERS
Mod.
V~
Hz
S/N
H
O
kPa
2
Do not use adaptors, multiple socket-outlets or cables of inadequate type and section
or with extension connections not compliant with plant engineering standards in
force.
•
If the system is new or barely used, have the water run a long time before making the
connection.
•
The water supply, temperature and pressure must be compatible with what is indicated on the
machine's technical data plate.
•
If the water's hardness is greater than 14 F (8 dH), we recommend you use the machine with
internal water softener (available on request). If the water's hardness is greater than 35 F (19.5
dH), we recommend you install an external water softener upline of the solenoid valve.
EMGA-webshop.nl
•
There must be an omnipolar type of main switch
that disconnects all contacts, including the
neutral, with a distance of at least 3 mm between
the open contacts and with safety circuit breaker
tripping or connected with fuses, to be sized or
calibrated in conformity with the power indicated on
the machine's data plate.
•
The main switch must be located on the electric line
close to the installation, and it must serve only one
appliance at a time.
•
Electric network voltage and frequency must coincide
with those given on the data plate.
•
There must be an effective earthing system in
conformity with the prevention standards in force for
operator and equipment safety.
•
The power supply cable (type H07RN-F only) must
not be pulled or crushed during normal operation or
routine maintenance.
•
The unipotential terminal fastened to the body must
be connected to a unipotential cable having a section
suited to the application.
•
Respect the polarities indicated in the wiring
kW
A
diagram.
°C
•
Consult that attached wiring diagram for additional
information.
The appliance is to be connected to the water network
with a hose. There must be a slide on-off, ball or gate
valve able to quickly and completely turn off the water
if necessary between the water network and the
appliance's solenoid valve. The on-off valve must be on
the line near and right before the appliance.
2.3 Electrical connection
2.4 Plumbing connection
Page 3 of 12
GB