5.1 52E CONTROL PANEL (INVERTER) - Connections
52E
Command
Function
1
2
NC
STOP
1
3
Opening
NO
1
4
Closure
NO
41
40
NC
Reversal safety
contact
1
8
NC
Reversal safety
contact
1
20
NO
Partial opening
1
11
NC
Closing position
1
13
Opening position
NC
1
9
Dead man
NC
M2
Safety device / Commands
M3
Position signal
M4
Interlock
M4A
Back
M5
Motor / brake motor
M6
Thermal motor
M7
Absolute encoder
Output
+
1
-
0
LAMP
-F
+F
200 V = / 0.2 A
U W V
M
3 ~
If on the programming menu (page 15 point 16)
Contact 1-2 enabled, opening of the contact STOPS the door
The closure of the contact activates the opening operation.
The closure of the contact activates the closing operation.
Opening the safety contact triggers a reversal of the movement (reopening)
during the closing operation.
Opening the safety contact triggers a reversal of the movement (reopening)
during the closing operation.
Closing of the contact activates a partial opening operation of the duration set
with the advanced menu.
Opening of the contact indicates the closing position. (max. 50 mA)
Opening of the contact indicates the opening position. (max. 50 mA)
By external selector
CONTROL PANEL CONNECTORS
Value
Power supply to accessories.
24V = / 0.5A
Power supply output for external accessories, including automation status
lamps.
Flashing light (FLM).
230 V~
Non-flashing signal (jumper ON on FML).
Activated during opening and closing operations.
Motor electric brake.
The output is active for the duration of both the opening and closing operation.
Three-phase motor.
230 V~ / 6 A
INPUTS
Description
J4
OPEN
SAFETY
OUTPUTS
Description
- 33 -
Brake resistance
Auxiliary panel card
Auxiliary safety card
EN
0DT872 01-12-2021