4.2. SLE CONNECTION (PRIMARY SAFETY)
Disconnect and remove from the SLE the cabling 9016. Insert the cabling 8457 and fit the connector on the SLE PCB
(fig.15).
15
4.3. CONNECTIONS TO THE CONTROL BOARD
Insert the cablings through the relevant cable glands:
- Encoder - cable gland 1
- SLE (8457) - cablegland 2
Connect all the cablings to the control board as shown at par. 5.1.
In the event that the door is subject to washing, it is preferable not to insert the cables into closed conduits (pipes or others)
to avoid water stagnation, but provide open supports to house the cables. Fig.16 schematically shows the wiring supplied
and their positioning.
16
230 V
9634
9635
9635
8457
Correctly size the line conductor cross-section by referring to the indicated absorption and taking the length and
installation of the cables into account.
0DT872 01-12-2021
9016
230V
Grey
- 32 -
- Photocells - cable glands 5 e 6
- Power supply (not provided) - cable gland 8
5
6
7
8
1
2
3
4
Tx
Rx
8457
Photocell RX
Photocell TX
Thermal protection (9634)
Power supply 230V
Motor (9635)
Brake (9635)
SLE (8457)
Encoder
Black