Problem
Drive is not functioning.
Drive moves in the
wrong direction.
Automatic control com-
mands are not carried
out.
The pre-set sunlight and
wind parameters cannot
be changed or are not
displayed.
Curtain/canopy does not
move into the end limit
position.
Wind alarm signal is
displayed although there
is no wind.

What to do if...?

Cause
Faulty connection.
Faulty connection.
The sliding switch is set
to manual mode.
No sensory equipment
is connected or the
connecting cable is
faulty.
1. Operating time is too
short.
2. End limit position is
not set.
1. Line break
2. Gusts of wind
Remedy
Check the connection.
Exchange ▲ and 
wires in the power
supply unit.
Set the sliding switch to
automatic mode.
Check the sensor
equipment, connecting
cable and connector
plug.
1. Adjust operating
time accordingly via the
Function menu.
2. Set end limit position
in the LIGHT END LIMIT
or TIME END LIMIT
setting menu.
1. Check cable and
replace if necessary.
2. Wait approx.15
minutes.