2.4 Connecting the blower

InTrOdUCTIOn:
The technical specifications of your radiator are shown on its nameplate.
Please note these down before installing it and before requesting any after-sales
assistance..
The electricity supply must be protected by a residual current device with a
maximum of 30 mA, especially when installed in a room containing a bathtub or
shower.
CLASS II COnneCTIOn (FrenCh mArkeT):
The appliance must be installed as described in this document and in accor-
dance with the applicable European and French standards, including CEI 60364.7.701
and NF C15-100, as well as the rules of good professional practice.
26
IP: protection level of your appliance against the
ingress of solid foreign bodies and water spray
Voltage and power required for installation
Appliance reference number
Class II: double insulated
OF: serial number
Manufacturer code
IImPOrTAnT The example shown only concerns a bathtub. For other bathroom fixtures,
please consult your installer.
nOTe:
The addition of a plug is strictly forbidden.
ImPOrTAnT The system must be fitted with an omnipolar circuit-breaker with a
minimum contact opening of 3mm.
When connecting the appliance to the mains, you must observe:
• the voltage indicated on the nameplate;
• conventional colour coding:
– Brown: live
– blue or grey: neutral
N (blue or grey)
L (brown)
CLASS I COnneCTIOn:
For other countries (apart from France), the appliance must be installed in
accordance with standards in force and with rules of good professional practice in the
country of use.
The flexible cable supplied with the appliance is designed to be connected to
the mains via a plug.
N
Neutral
Live