2. Installing your towel radiator and its
remote control
2.1 Choosing the position of your towel radiator
To get the most out of your appliance and enjoy the highest standards of comfort,
we recommend that you:
- install the appliance near places of high heat loss (windows, doors, etc., see
figure ①) wherever possible,
- ensure that an area of at least 50 cm in front of the appliance is clear of objects
which might hinder air circulation (furniture, chairs, etc.)
- ensure that the bottom of the appliance is positioned at least 15 cm above the
floor, see figure ①,
- leave at least 10 cm between the top of the appliance and any shelf,
- use mounting screws suitable for your wall,
- do not expose the radiator to intense or prolonged humidity.
ImPOrTAnT The heating appliance must not be placed underneath a power
outlet.
ImPOrTAnT This radiator must never be installed with its blower at the top, see
figure ②.
24
②
①
nOTe:
When installing your towel radiator, make
sure it is not resting on the blower (see
figure ③).
2.2 Choosing the position of the remote control
The remote control must under all circumstances be situated in the same room
as your towel radiator, with a maximum distance of 8m. You should preferably position
the remote control in direct line of sight, uninterrupted by any obstacle (wall, furniture,
etc.) to ensure that the infra-red signal is received correctly.
It can be secured to the wall or placed on the base provided (see chapter 3.1.1).
Before securing it in place, and after making the electrical connection of your
towel radiator, run an operating test. Make sure there are no objects likely to disrupt
signals between the remote control and the infra-red receiver on the towel radiator.
2.3 Connecting the towel radiator
In addition to the applicable regulations, we recommend you also check the
following:
- the water used in the heating circuit must not be aggressive or corrosive;
- the system must contain no traces of dissolved gases. In this event, thorough
degasification must be performed and the system must be bled at its high points.