MALFUNCTIONS
SYMPTOM
POSSIBLE CAUSE
Burner
You did not press the
extinguishes out
control knob long and/or
after igniting.
deep enough (at least 3
seconds).
Thermocouple (3) is dirty.
Glass plate broken.
Object fallen onto it.
Where the GAD type examination certificates of KIWA refer to the appliance category
"I2EK" this is understood as:
This appliance was configured for the appliance category K (I2K) and is suitable for the use of
G and G+ distribution gases according to the specifications as included in the NTA 8837:2012
Annex D with a Wobbe index of 43.46 – 45.3 MJ/m3 (dry, 0 °C, upper value) or 41.23 – 42.98
(dry, 15 °C, upper value).
This appliance can moreover be converted and/or again be calibrated for the appliance
category E (I2E) This therefore implies that the appliance: "is suitable for G+ gas and H gas or
is demonstrably suitable for G+ gas and can demonstrably be made suitable for H gas" within
the meaning of the "Dutch Decree of 10 May 2016 regarding amendment of the Dutch Gas
Appliances Decree...."
SOLUTION
Keep the control knob fully pressed for
at least 3 seconds between high and low
settings. This can be longer the first time,
because of the supply of gas.
Clean/dry the thermocouple.
Close the gas main switch and pull the plug
out of the socket. Contact the your installer.
EN 7