Domotica connections old / new
The user interface of the unit (see Figure 1) consists of:
• A push button (internal / external)
• A LED (internal / external)
• A potentiometer (external)
Figure 1: User interface
Push Button
The PCB itself contains the so-called internal push button (see 4 in Figure 1). An external push button can be connected
to the connector terminals on the PCB (see Figure 2). Both internal and external push button operates in exactly the same
way.
The push button has several functions, dependent on the duration of the button press, the state of the Burner Control and
the used application (see Table 1).
Table 1: operation of push button related to the duration of the pressed time
Duration
Burner Control
state
< 1s (short press)
Fault
< 1s (short press)
No fault
< 1s (short press)
No fault
< 1s (short press)
No fault
< 1s (short press)
No fault
10 - 15 s
-
> 15 s
-
Connection cross reference connections E.DFGT-SP → E.DFGT-03MC01
E.DFGT-SP_U1
3
4
5
6
Installatievoorschriften - True Vision - Ultra View - Open Fire Look
Application
-
IP/DBI
IP/DBI + second burner
SP
SP + second burner
-
-
E.DFGT-03MC01
GND
EXT/LED
GND
NTC/POT
Action
Reset of burner control
Off → On 100% load → On 0% load → Off
Off → On 100% load second on → On 100% load
second off → On 0% load → Off
Off → On 100% load → On 0% load → Pilot on →
Off
Off → On 100% load second on → On 100% load
second off → On 0% load → Pilot on → Off
RF Binding monde
None
6
3
6
1