4.5
Status values and advanced settings
WARNING: This operation is used to assist servicing and future repairs.
The default settings should only be modified by an experienced professional person.
The system's settings can be checked and adjusted via the remote control by following these
steps
Step 1 : Keep pressing
Step 2 : Press
Step 3 : Press
Note, some settings cannot be modified. Consult the settings table for further information.
Step 4 : Press
Step 5 : Press
Step 6 : Press
Parameter A
Parameters table
N°
Water temperature
A
Evaporator temperature
b
Ambient air temperature
c
Setting temperature in heating mode
d
Defrosting mode activation timer
E
Defrosting mode maximum duration
F
Setting temperature in cooling mode
G
Adjustment of temperature difference for restart
H
Automatic restart
J
Antifreeze protection - low air temperature
O
Evaporator temperature to enter defrosting mode
P
Evaporator temperature to exit defrosting mode
U
Reserved - Do not modify
t
4. Use
until you enter the settings verification mode.
and
for see the parameters.
to select the setting to be modified.
and
to adjust the setting value.
to set the new value.
to return to the main screen.
Description
Value 26
Range value
-19~99°C
-19~99°C
-19~99°C
15~40°C
10~80 min
5~30 min
8~28°C
1~10°C
0 = OFF
1 = ON
-10~15°C
-19~0°C
1~30°C
Default
Comment
value
Actual data
Actual data
Actual data
27°C
Adjustable
40 min
Adjustable
8 min
Adjustable
12°C
Adjustable
3°C
Adjustable
1
Adjustable
-5°C
Ajustable
-3°C
Ajustable
20°C
Ajustable
Reserved
EN | 15