Problem
Drive is not functioning.
The system does not
extend in response to a
manual command.
System is opening when
raining in spite of rain
sensor.
General conformity declaration
Becker-Antriebe GmbH hereby declares that the device Centronic SensorCon-
trol SC711 complies with the basic requirements and other relevant regulations
of the EC Directive R&TTE 1999/5/EC.
For use in the following countries: EU, CH
Subject to technical changes without notice.
18
What to do if ...?
Cause
1. Receiver is outside
of the radio operating
range.
2. The SC711 has not
been programmed into
the receiver.
The wind threshold
value of the transmitter
has been exceeded.
Wrong connection of
rain sensor .
Remedy
1. Reduce the distance
to the receiver.
2. Programme the
SC711.
Wait until wind abates.
Verify wiring.