Download Inhoudsopgave Inhoud Print deze pagina

Novy 1724 Gebruiksaanwijzing pagina 59

Flex zone
Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Mains
230V~1P+N 50Hz
400V~2P+N 50Hz 2 Phases + N
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
st
Put the 1
bridge between terminal 1 and 2, the 2
Attach the earth to the terminate "earth", the neutral N to terminal 4 or 5, the Phase L to one of
the terminals 1 or 2.
Biphase
400V~2P+N
Put a bridge between terminal 4 and 5.
Attach the earth to the terminate "earth", the neutral N to terminal 4 or 5, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
3 x 2.5 mm²
4 x 1.5 mm²
equipped with a faulty earth connection.
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
nd
between 4 and 5.
59
Protection
calibre
25 A *
16 A *

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

1726

Inhoudsopgave