Also the control handle can become really hot. Please use heat-resistant gloves!
Thermal - Bimetal air control
The Saey Duo is equipped with a bimetal air control mounted on the back of the stove. This bimetal
controls the amount of combustion air needed, depending on the amount of heat needed in the room.
This control must be opened completely while starting up and must be adjusted after 20 minutes until
the necessary heat is achieved.
In case that the chimney draft is too high, it can be diminished by adjusting this control switch.
the Bimetal in this way that when the stove reaches it full potential ( and max heat loss ) the air stream
is still sufficient.
OPEN:
Right position, as shown on figure 2 – maximum heat
CLOSED:
Left position – less heat
Adjust
55