USE OF THE APPLIANCE
Display
Display
Designation
0.
Zero
1...9
Power level
U
Pan detection
A
Heat accelerator
E
Error message
H
Residual heat
P
Booster
L
Locking
U
Keep warm
II
Pause
Ventilation
The cooling system is fully automatic. The cooling fan starts with a low speed when the calories
brought out by the electronic system reach a certain level. The ventilation starts his high speed
when the hob is intensively used. The cooling fan reduces his speed and stops automatically
when the electronic circuit is cooled enough.
STARTING-UP AND APPLIANCE MANAGEMENT
Before the first use
Clean your hob with a damp cloth, and then dry the surface thoroughly. Do not use detergent
which risks causing blue-tinted colour on the glass surface.
Induction principle
An induction coil is located under each heating zone. When it is engaged, it produces a variable
electromagnetic field which produces inductive currents in the ferromagnetic bottom plate of the
pan. The result is a heating-up of the pan located on the heating zone.
Of course the pan has to be adapted:
• All ferromagnetic pans are recommended (please verify it with a little magnet): cast iron
and steel pans, enamelled pans, stainless-steel pans with ferromagnetic bottoms...
• Are excluded: cupper, pure stainless-steel, aluminium, glass, wood, ceramic, stoneware,...
The induction heating zone adapts automatically to the size of the pan. With a too small diameter
the pan doesn't work. This diameter is varying in function of the heating zone diameter.
If the pan is not adapted to the induction hob the display will show [ U ].
Function
The heating zone is activated.
Selection of the cooking level.
No pan or inadequate pan.
Automatic cooking.
Electronic failure.
The heating zone is hot.
The boosted power is activated.
Control panel locked.
Maintain automatically of 70°C.
The hob is in pause.
56