Programming the ventilation/reverse position
Prerequisite: the roller shutter / blind is at the lower end limit.
1. Press and hold the ventilation/reverse position programming button s.
2. Press the UP button at the same time until you have reached the required
ventilation/reverse position. Adjustments can be made using the UP button
or DOWN buttons.
3. Release the ventilation/reverse position programming button s. The ventila-
tion/reverse position has now been saved.
The alarm signal control light will flash briefly three times.
Deleting the ventilation/reverse position
Press the ventilation/reverse position programming button s and hold for long-
er than 5 seconds. The ventilation/reverse position has now been deleted.
The alarm signal control light flash briefly three times.
Clean the device with a damp cloth only. Do not use a cleansing agent as this
may damage the plastic.
Nominal voltage
Switched current
System of protection
Protection class
Permissible ambient temperature
Type of installation
Cleaning
Technical data
230-240 V AC / 50-60 Hz
5 A /250 V AC for cos ϕ =1
IP 20
II
0 to +55 °C
Concealed Ø 58 mm wall-
mounted.
Exposed in appropriate exposed
casing.
de
en
fr
nl
25