Assembly and Operating Instructions
Explanations
MAN/AUTO sliding switch
In the „ " sliding switch setting, only manual command controls are carried out
(e.g.: UP, STOP, DOWN by pressing the relevant buttons).
In the „AUTO" sliding switch setting, automatic command controls are carried
out (control signals via group control inputs)
Alarm signal control light
When the alarm signal control light is illuminated, this indicates an alarm signal.
If there is a permanent switching signal at the group or individual control inputs
for more than 5 seconds, it is an alarm signal.
The ALARM SIGNAL function can be switched on/off using the encoding switch
1.
Group control
Group control is control of several drives at the same time.
RESET button
When the RESET button is pressed (with a ballpoint pen or similar), all switching
times, intermediate position and ventilation/adjustment position are deleted.
Intermediate position
The intermediate position is a position of the roller shutter/awning/blind be-
tween the upper and lower limits that can be freely selected. This position can
be reached from the upper position after programming.
Press the DOWN button twice in rapid succession to move to the inter-
mediate position.
Ventilation/reversing
The ventilation/reversing position is a position of the roller shutter/blind be-
tween the upper and lower limits that can be freely selected. Using this func-
tion, you can raise the shutter from the lower end limit until the ventilation slits
are open. The slats of the blind will be turned.
Press the UP button twice in rapid succession to move to the ventilation/revers-
ing position.
Drive controller
If the UC52 is used as a drive controller, the drive is connected directly to the de-
vice. External signals are converted into control commands. The coding switch
2 must be in the lower position.
22