3. Instructions

Use blind/shutter motors with mechanical or electronic limit switches only.
Check the blind/shutter motor for suitability in compliance with the
instructions set out in chapter 4 before using it in conjunction with the
RolloTec
Do not use isolating relays. With such relays, the blind/shutter control has no
power supply through the motor winding. Risk of malfunction.
Observe the instructions of the motor manufacturers concerning the switch-
over time and the maximum load factor (c.d.f.)
The RolloTec
in conjunction with one of the following attachments:
• RolloTec
• RolloTec
• RolloTec
• RolloTec
26
®
'Standard' insert without neutral conductor.
®
'Standard' insert without neutral conductor must only be used
®
pushbutton
®
radio-control pushbutton
®
memory pushbutton
®
clock timer or clock timer 'Easy'.
GB
The electronic interlocking of the attachment permits to obtain a minimum
switch-over time of approx. 1 second in the continuous run mode.
If a shutter motor is to be activated or deactivated – besides by local operation –
also from higher-level systems (e.g. centralized control), the RolloTec
dard' insert with inputs for extension controls must be used (neutral wire
required).
If it is necessary to prolong the sensor line, use an appropriate type of sensor
cable. Recommendation: J-Y(ST)Y 2x2x0.6 mm.
®