GB

1. Function

The RolloTec
installations without neutral conductor (N).
The existing mechanical shutter switch can therefore be replaced directly by a
comfortable control unit with the RolloTec
The RolloTec
RolloTec
System in a mounting box acc. to DIN 49073 (deep box recommended).
By replacing the attachment it is therefore possible to realize systems with
manual operation, comfortable operation by radio remote control or timer-
controlled fully automatic operation.
The insert is equipped with two mechanically interlocked relay power contacts.
The simultaneous activation of both moving directions of the shutter motor
connected is thus excluded.
22
®
'Standard' insert without neutral conductor is used in electrical
®
'Standard' insert without neutral conductor.
®
'Standard' insert without neutral conductor is a component of the
®
System and is used in conjunction with attachments of the RolloTec
Attention: Connect only one motor with limit switches and a
power consumption of 1000 W max. to each insert.
Do not use isolating relays.
It is absolutely necessary to check the motor for suitability as
described in chapter 4.
®
GB
The insert has 3 connecting terminals (1) and a 6-pole interface connector (2)
for connection of the attachment.
In addition, a 3-pole terminal block (3) can be placed into the insert (supplied
with inserts with sensor input).
This terminal block can be used to connect different sensors to the insert
when attachments with sensor input are installed:
• Sun protection / twilight sensor (order no. 0169)
• Glass breakage sensor (order no. 0170)