10CH DMX-chart 10-C (DMX CHANNEL1 set between values 225 and 255)
CHANNEL
VALUE
CH 2
000-255
11 different standard patterns
000-127
Fixed pattern size: from big (100%) to small (5%)
CH 3
128-169
Zooming in (from big to small + from slow to fast)
ZOOMING
170-209
Zooming out (from small to big + from slow to fast)
210-255
Zooming in & out (from slow to fast)
000-127
0° to 359° fixed positions around Y axis
CH 4
Y AXIS
128-191
Clockwise rolling around Y axis
ROLLING
192-255
Anticlockwise rolling around Y axis
000-127
0° to 359° fixed positions around X axis
CH 5
X AXIS
128-191
Clockwise rolling around X axis
ROLLING
192-255
Anticlockwise rolling around X axis
000-127
0° to 359° fixed positions around Z axis
CH 6
Z AXIS
128-191
Clockwise rolling around Z axis
ROLLING
192-255
Anticlockwise rolling around Z axis
000-127
128 different fixed positions along the X axis
CH 7
128-191
Clockwise moving along the X axis
X AXIS MOVING
192-255
Anticlockwise moving along the X axis
000-127
128 different fixed positions along the Y axis
CH 8
128-191
Clockwise moving along the Y axis
Y AXIS MOVING
192-255
Anticlockwise moving along the Y axis
000-016
Original colors
017-031
RED
CH 9
032-047
GREEN
COLOR
048-062
RED + GREEN (YELLOW)
063-160
Changing between red and green (from slow to fast)
161-255
Changing mix of 3 colors (from slow to fast)
CH 10
NOT USED
MAINTENANCE
 Make sure the area below the installation place is free from unwanted persons during servicing.
 Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
 The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
 Clean the external optics at least once every 30 days.
 Clean the internal optics at least every 90 days.
JB SYSTEMS
®
USER MANUAL
DESCRIPTION
9/63
TWIN EFFECT LASER
ENGLISH
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
AC 100~240V, 50/60Hz
Fuse:
250V 1.6A slow blow (20mm glass)
Total Power consumption:
28W
Sound Control:
Internal microphone
DMX connections:
3pin XLR male / female
DMX channels:
1 or 10 channels
DMX starting address:
001  512
Laser Power:
40mW Green CW laser (λ = 532nm)
80mW Red CW laser (λ = 650nm)
Laser radiation class:
3B
Beam diameter @ aperture:
<5mm
Divergence (each beam)
<2 mrad
Divergence (total output)
<160°
Working temperature:
15°C to 40°C
Laser Safety Standard:
EN/IEC 60825-1 Ed2, 2007-03
Size:
see picture below
Weight:
2,6kg
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
JB SYSTEMS