EN
ENVIRONMENTAL PROTECTION
This appliance is marked according the Directive on waste
electrical and electronic equipment (WEEE). By ensuring correct
disposal of this appliance you shall prevent potential negative
consequences for the environment and human health, which
could otherwise be caused by inappropriate waste handling of this
product.
The symbol
on the product, or on the accompanying
documents indicates that this appliance may not be treated as
household waste. Instead it should be handed over to the
applicable collection point for the recycling of electrical and
electronic equipment. Disposal must be carried out in accordance
with local environmental regulations for waste disposal. For more
detailed information about treatment, recovery and recycling of
this product, please contact your local city office, your household
waste disposal service or the shop where you purchased the
product.
HEATER TECHNICAL DESCRIPTION
The electric convector heater is a household appliance intended to
heat air in living rooms and maintain a specified temperature. See
page 2.
APPLIANCE INSTALLATION
The heater installation must strictly comply with standards
and rules in force in the country.
Carefully remove the convector from its packaging and store
џ
the packaging in a convenient place.
Do never use the heater without the supports for floor
џ
mounting. There is risk of fire!
Before turning on the heater for the first time, you need to
џ
install the supports as shown in Fig. 2. Place the convector
lying and put the supports at its bottom, making sure that the
power cord is put through as prescribed in the instructions
and does not interfere with the tightly fitted together unit
elements. Fix firmly the supports - hook the supports in the
openings and use the supplied screws (one screw for each
support). Sloped openings should point to the front panel of
the appliance.
Place the unit in a vertical operating position and make sure
џ
that the supports are installed properly before connecting it to
the mains.
The convector power cord plug can only be connected to a
џ
protected single phase power outlet with voltage 230 V~.
Convector heater should not be placed immediately in front of
џ
or under power outlets (sockets). The socket where the unit is
switched on must always be easily accessible to allow plug
disconnection as quickly as possible when needed. Fig 5.
When installing the appliance it is necessary to comply with
џ
the minimum prescribed distances from various obstacles
and surrounding objects as shown in Fig. 1.
Do not install the appliance in places with compulsory draft,
џ
which can disrupt the control settings (under natural or forced
ventilation apertures, fans, etc.).
When installing the heater on locations of high altitudes take
џ
into account that it may impact the temperature of the outlet
air (by increasing it with about 10 C when the altitude
changes with 1000 m)
о
15
HOW TO USE THE MECHANIC CONTROL
APPLIANCE RH01F20M-W
Appliance switching on and off
This heater is equipped with dual illuminated switch (pos. C on fig.
4), wich serves for selection of power:
"I" - 800W
џ
"II" - 1200W
џ
"I" + "II" - 2000W
џ
To switch on the appliance press the end of the key marked with
selected or desired power 'I' or 'II,' or both simultaneously. To
switch off the appliance press the end of the key marked with „0".
ATTENTION! The power selection switch is a functional key.
Complete turning off of the appliance is carried out ONLY by
taking the power supply cord out of the power supply socket.
Setting the room temperature
The heater is equipped with mechanical thermostat to set and
maintain the room temperature. To set the desired air temperature
in the room turn the thermostat knob (pos. E on fig. 4) in direction
from 1 to 7 on the scale. You may decrease temperature by turning
the knob in opposite direction. When reaching the desired room
temperature, turn the thermostat knob slowly (pos. E on fig. 4)
counter-clockwise until the double switch LED is switched off. Left
in such position the appliance shall automatically maintain the
temperature set.
Anti-freeze function
The thermostat is able to maintain a minimum temperature in the
room. This is the Anti-freeze function. The function is activated with
the knob in end position in direction of temperature decrease
marked with the star symbol
thermostat maintains a room temperature of 4-8 °C.
IMPORTANT! In order to allow the convector operates in Anti-
freeze mode it is necessary:
Its power cord be plugged in a socket in the room mains;
џ
The convector double switch be in position ON 'I' or 'II,' or both
џ
simultaneously.
The thermostat knob be in position marked with star.
џ
EN
on fig. 4. In this position the