12. Child lock
Activate child lock:
Press 【+】and 【-】at the same time as long as 3 seconds to activate the child lock. When the mobile
air conditioner is in child lock, the control panel will be blocked.
To unlock the child lock:
1. Press 【+】and 【-】at the same time as long as 3 seconds to unlock the child lock.
2. It is also possible to remove the plug from the wall socket to deactivate the child lock.
Note:
The child lock is a safety function. Never leave the device unattended near children, people with a
mental disability or pets.
13. Condensate drain
After completion of the cold storage or heat storage function, the unit will automatically drain the
condensed water if no other function is active. The water will be stored in het reservoir of the device.
14. Drain
In the event of a water alarm you must drain the water to the correct water level for the correct
operation of the mobile air conditioner. Follow these steps to drain the water in the internal water
reservoir of the machine.
1. Screw the drain button on the rear side separately (water outlet), turn the drain hose to the
water outlet connection, and connect the other end to a drain.
2. Plug in the power cord and press the power button on the control panel.
3. Press 【drainage】and hold the discharge button for longer than 3 seconds pressed. The
draining of the water from the reservoir will start automatically.
4. If the water level is above the working water level, the drain only stops when it reaches the
working water level. If it is necessary to completely drain the water in the water reservoir,
repeat step 3 to continue draining until the reservoir is completely empty.
5. After the water has been drained from the reservoir, the drain pump will be automatically
switched off.
6. Remove the drain hose and screw the cover lid back on.