Download Inhoudsopgave Inhoud Print deze pagina

Danger; Application And Field Of Use; Attention; Structure And Functional Description - KSR KUEBLER UTN EX Series Montage- En Bedieningshandleiding

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Danger!

There is a risk of poisoning or suffocation when working in containers. Relevant
personal protection measures (e.g. respiratory devices, protective clothing, etc.)
must be taken before work is carried out.
The UTN...EX container may be pressurised. The interior of the UTN...EX container may
contain a hot, toxic, caustic or explosive medium. There is a risk of injury due to liquid
spraying out of the container, burns on the hands, arms, feet and face as well as caustic
burns, intoxication (poisoning) or explosion. The container must be depressurised prior to
opening it.

Application and field of use

An approval has been issued for the UTN...EX for use as explosion-protected equipment within the
scope of application defined by EC Guideline 94/9/EC in hazardous areas. They comply with the
specifications regulating use of mechanical equipment in explosion risk areas.
The technical data in these operating instructions must be complied with.
See the installation and operating instructions for the accessory fittings and instruments
(level transmitter MG, magnetic switch, etc.).
Ignition protection UTN ... EX without Magnetic roller display:
Ignition protection UTN ... EX with Magnetic roller display:

Attention !

The KSR Top Mounted Level Indicator (UTN...EX) may only be used within the maximum
pressure and temperature levels listed on the type plate. Exceeding these parametric
levels may result in malfunction or destruction of the UTN...EX as well as to personal injury
and property damage.
All of the materials used for the UTN...EX guide rod and float must be resistant to the medium the
level of which is to be monitored. The maximum values listed on the type plate must be complied
with to ensure operation free of malfunction.
At temperatures exceeding 60°C, a sign must be attached to flanges, pipes, casing, etc. clearly
warning of the risk of burn injuries.

Structure and functional description

The KSR Top Mounted Level Indicator is mounted on the top of the tank by means of a suitable
process connection (flange or thread). It consists of a chamber and a float with guide rod and
magnetic system attached to it. The permanent magnet system, connected by guide rod with the
float, transfers the amount of liquid via the magnetic system in the chamber, contactlessly to the
KSR Magnetic Rollers,.
ATEX (94/9/EG) directive corresponding devices installed outside at the chamber

Removal of transport packaging and transport safety devices

Carefully remove the UTN...EX Top Mounted Level Indicator from the transport packaging.
Please comply with the instructions on the shipping packaging and remove all transport retention
elements before taking out UTN...EX Top Mounted Level Indicator. Never exert force to remove
the UTN...EX Top Mounted Level Indicator from the package!
Remove any float retainer bands before installing the UTN...EX Top Mounted Level Indicator.
Make sure all packaging elements have been removed and that the guide rod can move freely
within the chamber.
MBUTNEX.doc
Float and chamber Zone 0 / Magnetic roller display Zone 1
Level Sensors
(MG...),
Magnetic Switches
or other II 2G EEx / II 1G EEx
II 1 G c T1...T6
II 1/2 G c T1...T6
12 / 21