8. Troubleshooting
PROBLEM
Burner won't light
Burner won't stay lit
Burner flame is low
Note: Do not operate
appliance below 5 ˚C
Carbon build-up
Flash back (flame inside
burner)
Thick black smoke
If you can not solve trouble according to one of the mentioned solution, please contact your
dealer or Distributor Responsible.
CONDITON
Control knob is not in
Maximum position
(big flame).
LPG cylinder valve is
closed /Empty.
Blockage in the injector.
Air in the gas circuit.
Low gas pressure.
Igniter fails.
Dirty build up around bur-
ner. Low flames or not full
running around the burner.
Thermocouple is not
operating correctly.
Low Gas pressure.
Outdoor temperature is
greater than 5 ˚C and LPG
cylinder is less than
25 % full.
Gas pipe is bent or kinked.
Control knob is fully
Maximum position (big
flame).
Dirty or film on burner.
Burner ports are blocked.
Blockage in the burner.
- 24 -
SOLUTION SUGGESTED
Turn control knob in Maximum
position (big flame).
Open the valve / Replace LPG
cylinder with a new one.
Clean or replace injector.
Open gas line and bleed it (pressing
control knob in) for not over 1 minu-
te or until you smell gas.
Replace LPG cylinder with a new
one.
Use match to light burner; change
battery or obtain new ignite and
replace it.
Clean dirty around the burner.
Flame spreader holes partially clo-
sed; clean the burner.
Replace thermocouple (FSD).
Replace LPG cylinder with a new
one.
Replace LPG cylinder with a new
one.
Straighten hose and perform
leakage test on gas pipe.
Turn control knob to"OFF" position
(full disk), let cool to room tempera-
ture and check burner and orifices
for blockage.
Clean burner.
Switch OFF the appliance. Close
LPG cylinder valve. Wait 2 minutes,
following the ignition procedure.
Ignite burner. If problem continuous,
switch-off. Contact your dealer.
Turn control knob to "OFF" position,
let the appliance to cool at room
temperature and remove block-
age and clean burner inside and