Setting the output voltage of output C
Output C can be used independently of the set operating mode (series-tracking/series/parallel/
individual).
Remove connected consumers from output C.
Switch on the mains power unit at the power switch (1). The operating display (2) lights up and the cur-
rent and voltage display appears on the display.
Press the button "show value" (13) and keep this depressed while setting the voltage. The display of out-
put B shows the voltage and current of output C.
With the rotary control "V-adjust" (12), you can set the output voltage for output C.
After setting the voltage, let go of the button (13) again.
A fixed current limitation of approx. 1.5 A is set for output C, which cannot be changed.
When this current limit is reached, the red indicator "overload" (11) lights up.
You can check the corresponding voltage and current values at any time by pressing
the button "show value" (13).
Connecting a Consumer
When connecting a consumer, make sure that it is connected to the power
unit when switched off. The maximum current consumption of the device to
be connected must not exceed the capacity indicated in the technical specifi-
cations.
For series connection of the outputs A and B or several power units, voltages > 75
VDC are generated, whose contact can be fatal. As of this voltage, you may only
use insulated accessories.
Avoid the use of non-insulated metallic cables and contacts. All of these spots
must be covered with suitable, flame-resistant insulation materials or by means
of other measures, which serve to prevent direct contact and short circuits.
Ensure a sufficient cable diameter for the intended current.
29