SLECHTE WERKING
REGELING MOTOR IS
NIET ACTIEF
STUUR IS
ONNAUWKEURIG
OVERVERHITTING
TRACTIEMOTOR
Pagina74
OORZAAK
ACCUNIVEAU LAAG
GEBLOKKEERD WIEL
STROOMONDERBREKING
DEFECTE
MICROSCHAKELAAR AAN
STUURSTANG
UITSCHAKELING
ELEKTRONISCHE
VERBINDING
POTENTIOMETER NIET
AFGESTELD
STORING MOTOR
ELEKTRONISCHE
AFSTELLING MISLUKT
POTENTIOMETER NIET
AFGESTELD
TIJD OM DE MOTOR IN TE
SCHAKELEN IS TE LANG
OPLOSSING
OPLADEN
GA WEG VAN HINDERNISSEN
EN KUILEN
ZEKERINGEN CONTROLEREN
EN VERVANGEN
CONTROLER EN VERVANG
CONTROLEER OF ALLE
STROOM- EN SERVICEKABELS
CORRECT OP DE
AANSLUITKLEMMEN ZIJN
BEVESTIGD EN OF DE
CONNECTOREN CORRECT
ZIJN GEPLAATST
LAAT DIT CONTROLEREN BIJ
EEN GESPECIALISEERDE
WERKPLAATS.
REPAREREN OF VERVANGEN
LAAT DIT CONTROLEREN BIJ
EEN GESPECIALISEERDE
WERKPLAATS. RAADPLEEG DE
HANDLEIDING VAN HET
AFSTELSYSTEEM DIE DOOR
DE BETREFFENDE FABRIKANT
IS VERSTREKT.
LAAT DIT CONTROLEREN BIJ
EEN GESPECIALISEERDE
WERKPLAATS.
VERMINDER DE
INSCHAKELTIJD.
VERTALING VAN DE ORIGINELE INSTRUCTIES
Valla 25E mobiele kraan