Installation
General
The fitting of the appliance should only be
carried out by a registered Corgi gas fitter.
The appliance is not connected to the flue gas
outlet channel.
Electrical connection 230 V - 50 Hz.
The electrical connection must comply
n
with national and local regulations. For the
Netherlands this includes the NEN 1010
amongst other standards.
Wall socket and plug must be accessible at
n
all times.
Gasconnection: RC 1/2" (ISO 7/1-RC 1/2)
The gas connection must comply with
n
national and local regulations. For the
Netherlands this includes the GAVO
regulations (NEN 1078). Amongst other
things these regulations instruct that:
– only approved materials are to be used.
Attention: The type of gas and the country for
which the appliance has been designed
are indicated on the ratings plate. The
appliance is set in the factory for G25/G25.3
(natural gas) with a pressure of 25 mbar.
Appliance category I II2L3B/P + II2EK3B/P
Connect the oven directly to the mains.
n
This is because the oven can reach high
temperatures. It can also be connected
with a specially designed gas hose. Attach
this hose at the side of the oven to prevent
it touching any hot parts. A gas tap, which
is easily accessible, should always be
used for the appliance.
Dimensions
500
(EFG609)
600
850
front view
600
side view
fig. 10
EN 17