Communicatieobjecten: Verwarming (8 Bytes)
237, 336, 435, 534, 633, 732, 831, 930, 1029, 1128, 1227, 1326 - Thermostaat x - Instelwaarde verwarming (8 -
Byte - 275.100 DPT_TempRoomSetpSetF16 [4])
Communicatieobjecten: Koeling (2 Bytes)
238, 337, 436, 535, 634, 733, 832, 931, 1030, 1129, 1228, 1327 - Thermostaat x - Comfort temperatuur
setpoint koeling (2 - Byte - 9.001 DPT_Value_Temp)
239, 338, 437, 536, 635, 734, 833, 932, 1031, 1130, 1229, 1328 - Thermostaat x - Standby setpoint koeling (2 -
Byte - 9.001 DPT_Value_Temp)
240, 339, 438, 537, 636, 735, 834, 933, 1032, 1131, 1230, 1329 - Thermostaat x - Nacht setpoint koeling (2 -
Byte - 9.001 DPT_Value_Temp)
241, 340, 439, 538, 637, 736, 835, 934, 1033, 1132, 1231, 1330 - Thermostaat x - Setpoint
Overhittingsbeveiliging koeling (2 - Byte - 9.001 DPT_Value_Temp)
Communicatieobjecten: Koeling (8 Bytes)
242, 341, 440, 539, 638, 737, 836, 935, 1034, 1133, 1232, 1331 - Thermostaat x - Instelwaarde koeling (8 - Byte
- 275.100 DPT_TempRoomSetpSetF16 [4])
Elk communicatie-object heeft een statusindicatie object waarmee de insteltemperatuur wordt doorgegeven.
Communicatieobjecten: Statusindicatie verwarming (2 Bytes)
247, 346, 445, 544, 643, 742, 841, 940, 1039, 1138, 1237, 1336 - Thermostaat x - Status indicatie comfort
setpoint verwarming (2 - Byte - 9.001 DPT_Value_Temp)
248, 347, 446, 545, 644, 743, 842, 941, 1040, 1139, 1238, 1337 - Thermostaat x - Status indicatie standby
setpoint verwarming (2 - Byte - 9.001 DPT_Value_Temp)
249, 348, 447, 546, 645, 744, 843, 942, 1041, 1140, 1239, 1338 - Thermostaat x - Status indicatie setpoint
nacht verwarming (2 - Byte - 9.001 DPT_Value_Temp)
250, 349, 448, 547, 646, 745, 844, 943, 1042, 1141, 1240, 1339 - Thermostaat x - Status indicatie
vorstbeveiliging verwarming (2 - Byte - 9.001 DPT_Value_Temp)
Communicatieobjecten: Statusindicatie verwarming (8 Bytes)
251, 350, 449, 548, 647, 746, 845, 944, 1043, 1142, 1241, 1340 - Thermostaat x - Status indicatie setpoints
verwarming (8 - Byte - 275.100 DPT_TempRoomSetpSetF16 [4])
Communicatieobjecten: Statusindicatie koeling (2 Bytes)
252, 351, 450, 549, 648, 747, 846, 945, 1044, 1143, 1242, 1341 - Thermostaat x - Status indicatie comfort
setpoint koeling (2 - Byte - 9.001 DPT_Value_Temp)
253, 352, 451, 550, 649, 748, 847, 946, 1045, 1144, 1243, 1342 - Thermostaat x - Status indicatie standby
setpoint koeling(2 - Byte - 9.001 DPT_Value_Temp)
254, 353, 452, 551, 650, 749, 848, 947, 1046, 1145, 1244, 1343 - Thermostaat x - Status indicatie setpoint
nacht koeling(2 - Byte - 9.001 DPT_Value_Temp)
255, 354, 453, 552, 651, 750, 849, 948, 1047, 1146, 1245, 1344 - Thermostaat x - Statusindicatie instelwaarde
vorstbeveiliging koeling (2 - Byte - 9.001 DPT_Value_Temp)
Communicatieobjecten: Statusindicatie koeling (8 Bytes)
256, 355, 454, 553, 652, 751, 850, 949, 1048, 1147, 1246, 1345 - Thermostaat x - Status indicatie setpoints
koeling (8 - Byte - 275.100 DPT_TempRoomSetpSetF16 [4])
TYM646T - TYM646R
129