2.2
(Manual)control
Depending on the model, the gas control block is positioned either:
•
behind a stainless steel door on the underside of the appliance
•
mounted in the middle of the floor plate of the appliance
•
behind the frame (accessible by tilting the frame upwards)
These appliances are fitted with a manual GV36 gas control (see fig.2.1) that optionally
can be adjusted with a G30 remote control.
The pilot light always has to be lit before the main burner can be used. Rotary knob A
functions as a main valve and has to be used to lit the pilot light. Use rotary knob B to
adjust the height of the flames.
Warning! When the pilot extinguishes, for whatever reason, you should wait at least 5
minutes before trying again. Possible causes of pilot extinguish are:
•
operation error
•
interference of the safety device
•
failure in the pilot flame system
Contact a qualified installer when the appliance extinguishes regularly.
2.2.1 Pilot ignition
To ignite the pilot light:
•
simultaneously press and turn rotary knob A anti-clockwise to the
position at the
element starts to ignite
•
hold the knob in this position for some seconds to clear the air from the pipe and
allow gas to reach the pilot burner
•
if the pilot light does not light return to the
•
hold the knob for about ten seconds after the pilot light ignites
•
turn the knob anti clockwise to the
burner to be ignited (see main burner ignition)
2.2.2 Pilot extinguish
To extinguish the pilot light:
•
first turn rotary knob B clockwise till the
•
turn rotary knob A clockwise to the
•
simultaneously press and turn rotary knob A clockwise to the
(spark) position a click will be heard and the piezo-electric
(large flame) position to allow the main
(small flame) position
(stop) position and restart
(off) position
(off) position
UK
IRL
(small flame)
8 <
<
<
<