Download Inhoudsopgave Inhoud Print deze pagina

Daikin Altherma EHVH04S18CBV Installatiehandleiding pagina 22

Verberg thumbnails Zie ook voor Altherma EHVH04S18CBV:
Inhoudsopgave

Advertenties

8 Technische gegevens
Vertaling van tekst op bedradingsschema
Engels
(1) Main power connection
For preferential kWh rate power
supply
Indoor unit supplied from outdoor Binnenunit gevoed door buiten
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
Use normal kWh rate power
supply for indoor unit
(2) User interface
Only for remote user interface
option
SWB
(3) Ext. thermistor
SWB
(4) Field supplied options
230 V AC supplied by PCB
5 V DC pulse detection (voltage
supplied by PCB)
Continuous
DHW pump
DHW pump output
Electrical meters
For safety thermostat
Inrush
Max. load
Normally closed
Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
SWB
(5) Domestic hot water tanks
3 wire type SPST
Installatiehandleiding
22
Vertaling
(1) Aansluiting
hoofdstroomtoevoer
Voor elektrische voeding met
kWh-voorkeurtarief
Elektrische voeding met normaal
kWh-tarief
Alleen voor normale voeding
(standaard)
Alleen voor elektrische voeding
met voorkeur kWh-tarief (buiten)
Buitenunit
Contact voor de voeding met
voorkeur kWh-tarief: 16 V DC-
detectie (spanning geleverd door
printplaat)
Gebruik elektrische voeding met
normaal kWh-tarief voor
binnenunit
(2) Gebruikersinterface
Alleen voor de optie
afstandsgebruikersinterface
Schakelkast
(3) Externe thermistor
Schakelkast
(4) Niet meegeleverde opties
230 V AC geleverd door
printplaat
5 V DC pulsdetectie (spanning
geleverd door printplaat)
Continue stroom
Pomp voor warm tapwater
Uitgang pomp voor warm
tapwater
Elektriciteitsmeters
Voor veiligheidsthermostaat
Inschakelstroomstoot
Maximale belasting
Normaal gesloten
Normaal geopend
Contact voor de
veiligheidsthermostaat: 16 V DC-
detectie (spanning geleverd door
printplaat)
Afsluiter
Schakelkast
(5) Warm tapwatertanks
type 3 geleiders SPST
Engels
Anti-legionella heater power
supply
For ***
For *** or ***
SWB
(6) Optional BUH
SWB
(7) Anti-legionella heater power
supply
For ***
(8) Option PCBs
Alarm output
Changeover to ext. heat source
For digital I/O PCB option
For solar pump station
Max. load
Min. load
Only for ***
Only for demand PCB option
Only if no ***
Options: boiler output, solar
pump connection (only EHBH*),
alarm output
Options: bottom plate heater OR
On/OFF output
Outdoor unit
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Refer to operation manual
Solar pump connection
Space C/H On/OFF output
Switch box
To bottom plate heater
(9) External On/OFF thermostats
and heat pump convector
Additional LWT zone
For external sensor (floor/
ambient)
For heat pump convector
For wired thermostat
For wireless thermostat
Main LWT zone
EHVH04+08S18CBV + EHVH08~16S26CBV
Vertaling
Elektrische voeding voor anti-
legionellaverwarming
Voor ***
Voor *** of ***
Schakelkast
(6) Optionele back-upverwarming
Schakelkast
(7) Elektrische voeding voor anti-
legionellaverwarming
Voor ***
(8) Optionele printplaten
Alarmuitgang
Omschakeling naar externe
warmtebron
Voor optie digitale I/O-printplaat
Voor zonnepompstation
Maximale belasting
Minimale belasting
Alleen voor ***
Alleen voor optie vraag-printplaat
Alleen indien geen ***
Opties: boileruitgang, aansluiting
pomp zonnesysteem (alleen
EHBH*), alarmuitgang
Opties: bodemplaatverwarming
OF AAN/UIT-uitgang
Buitenunit
Digitale inputs
vermogenbeperking: 12 V DC /
12 mA detectie (spanning
geleverd door printplaat)
Raadpleeg de
gebruiksaanwijzing
Aansluiting pomp zonnesysteem
Uitgang ruimtekoeling/-
verwarming AAN/UIT
Schakelkast
Naar bodemplaatverwarming
(9) Externe AAN/UIT-
thermostaten en
warmtepompconvector
Aanvoerwatertemperatuur
secundaire zone
Voor externe sensor (vloer of
omgeving)
Voor warmtepompconvector
Voor bedrade thermostaat
Voor draadloze thermostaat
Aanvoerwatertemperatuur
primaire zone
Daikin Altherma - Lage-temperatuur-Split
4P449977-1B – 2018.02

Advertenties

Inhoudsopgave
loading

Inhoudsopgave