Tabel lokale instellingen
Breadcrumb
Lokale code Naam instelling
A.2.1.2
[E-01]
Compressortype
A.2.1.3
[E-02]
Softwaretype binnen
A.2.1.4
[E-03]
Stappen backupverwarming
A.2.1.5
[5-0D]
Type BUH
A.2.1.6
[D-01]
Geforceerd uit contact
A.2.1.7
[C-07]
Unitbestur.methd
A.2.1.8
[7-02]
Aantal zones AWT
A.2.1.9
[F-0D]
Pompbedrijfsmodus
A.2.1.A
[E-04]
Energie besparen mogelijk
A.2.1.B
Loc. gebruik.interface
└─ Opties
A.2.2.1
[E-05]
Warmtapwaterbedrijf
A.2.2.3
[E-07]
Type warmtapwatertank
A.2.2.4
[C-05]
Primair contact
A.2.2.5
[C-06]
Sec. contact
A.2.2.6.1
[C-02]
Digitale I/O-printplt
A.2.2.6.2
[D-07]
Digitale I/O-printplt
A.2.2.6.3
[C-09]
Digitale I/O-printplt
A.2.2.6.4
[F-04]
Digitale I/O-printplt
A.2.2.7
[D-04]
Vraag-printplaat
A.2.2.8
[D-08]
Externe kWh-meter 1
A.2.2.9
[D-09]
Externe kWh-meter 2
A.2.2.A
[D-02]
Warmtapwaterpomp
A.2.2.B
[C-08]
Extrn sensor
└─ Capaciteiten
A.2.3.1
[6-02]
Boosterverwarming
A.2.3.2
[6-03]
BUH: stap 1
A.2.3.3
[6-04]
BUH: stap 2
A.2.3.6
[6-07]
Bodemplaatverwarm
└─ Bedrijf
└─ Instellingen AWT
└────────────────── Primair
A.3.1.1.1
AWT instelpuntstand
A.3.1.1.2.1
[9-01]
Temperatuurbereik
A.3.1.1.2.2
[9-00]
Temperatuurbereik
A.3.1.1.2.3
[9-03]
Temperatuurbereik
A.3.1.1.2.4
[9-02]
Temperatuurbereik
A.3.1.1.5
[8-05]
Aangepaste AWT
A.3.1.1.6.1
[F-0B]
Afsluiter
A.3.1.1.6.2
[F-0C]
Afsluiter
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*
Ext BUH bron
Solarkit
Alarm-output
Bodemplaatverwarm
Minimumtemp (verwarm)
Maximumtemp (verwarm)
Minimumtemp (koelen)
Maximumtemp (koelen)
Thermo AAN/UIT
Koeling
Bereik, stap
Standaardwaarde
R/O
0: 8
1: 16
R/O
0: Type 1
1: Type 2
R/O
0: Geen BUH
1: 1 stap
2: 2 stappen
R/W
0: 1P,(1/2)
1: 1P,(1/1+2) (*3)
2: 3P,(1/2)
3: 3P,(1/1+2)
4: 3PN,(1/2)
5: 3PN,(1/1+2) (*4)
R/W
0: Nee
1: Open tarief
2: Gesloten tarief
3: Thermostaat
R/W
0: Besturing AWT
1: Bst xt kmrthrms
2: Best. kmrthrmst
R/W
0: 1 AWT-zone
1: 2 AWT-zones
R/W
0: Continu
1: Monster
2: Verzoek
R/O
0: Nee
1: Ja
R/W
0: Op unit
1: In de kamer
R/W
0: Nee (*1)
1: Ja (*2)
R/W
0~6
0: Type 1 (*1)
1: Type 2 (*2)
R/W
1: Thermo AAN/UIT
2: Verw/koel vraag
R/W
1: Thermo AAN/UIT
2: Verw/koel vraag
R/W
0: Nee
1: Bivalent
2: -
3: -
R/W
0: Nee
1: Ja
R/W
0: Normaal open
1: Norm. gesloten
R/W
0: Nee
1: Ja
R/W
0: Nee
1: Best. energ.vbr
R/W
0: Nee
1: 0,1 impuls/kWh
2: 1 impuls/kWh
3: 10 impuls/kWh
4: 100 impuls/kWh
5: 1000 impuls/kWh
R/W
0: Nee
1: 0,1 impuls/kWh
2: 1 impuls/kWh
3: 10 impuls/kWh
4: 100 impuls/kWh
5: 1000 impuls/kWh
R/W
0~4
0: Nee
1: Secund retour
2: Disinf. shunt
R/W
0: Nee
1: Buitensensor
2: Kamersensor
R/W
0~10kW, stap: 0,2kW
3kW (*1)
0kW (*2)
R/W
0~10kW, stap: 0,2kW
3kW
R/W
0~10kW, stap: 0,2kW
0kW (*3)
6kW (*4)
R/W
0~200W, stap: 10W
0W
R/W
0: Absoluut
1: Weersafh.
2: Abs+geprog
3: Weersafh+geprog
R/W
15~37°C, stap: 1°C
25°C
R/W
37~afhankelijk van buitenunit, stap: 1°C
55°C
R/W
5~18°C, stap: 1°C
5°C
R/W
18~22°C, stap: 1°C
22°C
R/W
0: Nee
1: Ja
R/W
0: Nee
1: Ja
R/W
0: Nee
1: Ja
3/9
Instelling installateur verschilt van
standaardwaarde
Datum
Waarde
4P383508-1B - 2017.04