Frequentie-omvormers (wisselstroomaandrijving) PowerFlex 400 Snelstart Nederlands-23
Nr.
Parameter
A181 [Motor overbelasting
Select]
A182 [Aandrijving
overbelastingsmodus]
A183 [SW-stroomuitschakeling] 0.0/(Aandrijving
A184 [Belasting uitvalpeil]
A185 [Belasting uitvaltijd]
A186 [Tijd Uitvalfout]
A187 [Bus Reg. Modus]
A188 [Dode frequentie 1]
A189 [Dode frequentiezone 1] 0.0/30.0 Hz
A190 [Dode frequentie 2]
A191 [Dode frequentiezone 2] 0.0/30.0 Hz
A192 [Dode frequentie 3]
A193 [Dode frequentiezone 3] 0.0/30.0 Hz
A194 [Compensatie]
A195 [Meters opnieuw
instellen]
A196 [Meetpunt Sel]
A197 [Fout wissen]
A198 [Programma-vergrendelin
g]
A199 [Motor NP-polen]
A200 [Motor NP vollaststroom] 0.1/(aandrijving
Parameters kaarten hulprelaisgroep
Nr.
Parameter
R221
[Relais uit3 Sel]
R224
[Relais uit4 Sel]
R227
[Relais uit5 Sel]
R230
[Relais uit6 Sel]
R233
[Relais uit7 Sel]
R236
[Relais uit8 Sel]
R222
[Relais uit3 peil]
R225
[Relais uit4 peil]
R228
[Relais uit5 peil]
R231
[Relais uit6 peil]
R234
[Relais uit7 peil]
R237
[Relais uit8 peil]
[Relais uitX Select] instelling
6
7
8
9
10
12
R239 [Aux Motormodus]
R240 [Aux Motor Aant]
R241
[Aux 1 Startfreq]
R244
[Aux 2 Startfreq]
R247
[Aux 3 Startfreq]
Min/Max
Weergave/Opties
0/2
0 = "No Derate"
0/3
0 = "Disabled"
1 = "Reduce CLim"
0.1 Amp
amp × 1.8)
0.0/aandrijving amp 0.1 Amp
0/9999 sec
1 sec
0/5
0 = "60 Seconds"
1 = "120 Seconds"
2 = "240 Seconds"
0/1
0 = "Disabled"
0/320 Hz
1 Hz
0.1 Hz
0/320 Hz
1 Hz
0.1 Hz
0/320 Hz
1 Hz
0.1 Hz
0/3
0 = "Disabled"
1 = "Electrical"
0/2
0 = "Ready/Idle"
1024/65535
1
0/2
0 = "Ready/Idle"
0/3
0 = "Unlocked"
1 = "Locked" (All)
2/40
1
0.1 Amp
amp × 2)
Min/Max
Weergave/Opties
0/23
0 = "Ready/Fault"
1 = "At Frequency"
2 = "MotorRunning"
3 = "Hand Active"
4 = "Motor Overld"
5 = "Ramp Reg"
6 = "Above Freq"
7 = "Above Cur"
8 = "Above DCVolt"
0.0/9999 Hz
0.1
[Relais uitX peil] min/max
0/320 Hz
0/180%
0/815 Volt
0/100%
1/180 gr
0/1
0/1
0 = "Disabled"
1/6
1 = "1 Aux Mtr"
2 = "2 Aux Mtr"
3 = "3 Aux Mtr"
0.0/320.0 Hz
0.1 Hz
1 = "Min Derate"
2 = "Min Derate"
2 = "Reduce PWM"
3 = "Both-PWM 1st"
3 = "360 Seconds"
4 = "480 Seconds"
5 = "Flt Disabled"
1 = "Enabled"
2 = "Mechanical"
3 = "Both"
1 = "Reset MWh"
2 = "Reset Time"
1 = "Reset Fault"
2 = "Clear Buffer"
2 = "Locked" (Not Network)
3 = "Locked" (P035, A170)
9 = "Above Anlg 2"
10 = "Above PF Ang"
11 = "Anlg In Loss"
12 = "ParamControl"
13 = "Retries Exst"
14 = "NonRec Fault"
15 = "Reverse"
16 = "Logic In 1"
17 = "Logic In 2"
23 = "Aux Motor"
1 = "Enabled"
4 = "1 Mtr + Swap"
5 = "2 Mtr + Swap"
6 = "3 Mtr + Swap"
Standaard
0
3
0.0
(uitgeschakeld)
0.0
(uitgeschakeld)
0
(uitgeschakeld)
0
1
0 Hz
0.0 Hz
0 Hz
0.0 Hz
0 Hz
0.0 Hz
3
0
1024
0
0
4
Nominale Amp
Standaard
0
0.0
0
1
50.0 Hz