E2
Overheat of
temperature
sensor for cooking
zone
E3
Wrong pot
E5
Mains voltage error Mains voltage too
E6
Mains-sync-Pulse
error
E8
Fan error
E9
Temperature
sensor on inductor
defective
EA
Hardware fault
E/H
Invariable resistor
fault
U400
Wrong connection
(*) Hiervoor dient de Boretti service afdeling geraadpleegd te worden.
BEDIENPANEEL
Empty cookware -
Wrong cookware
An impermissible
working range
is reached or
exceeded in the
system
low or too high
Mains frequency
outside the
permissible
frequency range
Fan no longer turns,
is blocked or short
circuit possible
Inductor NTC
delivers implausible
values, points to
sensor defect.
defect sensor-
Wrong values of
stored data - gate
voltage topo low or
too high
No temperature
change of the
cooking zone sensor
at power drain
Wrong connection
was detected
34
Do not heat-up empty pots -
Use appropriate cookware
1.This error is reset after 30s;
the cooking zone can be used
again.
2.The power unit must be
replaced if the error continues
to be displayed even when
no pot/*pan is present on the
cooking zone (*)
Check wiring and voltage
supply on the system;
replace the power unit if
everything is correct (*)
- Check mains connection and
wiring; (*)
- Replace the power unit (*)
Air intake blocked,e.g. through
piece of paper. Replace
defective fan (*)
Replace inductor (*).
Replace the power unit (*)
Replace the power unit (*)
Induction module must cool
Correcting mais connection