5. Technical data
DX 460 GR tool
Weight
Tool length
en
Recommended maximum fastening rate
Cartridges
Power regulation
Right of technical changes reserved
6. Before use
aa
6.1
Tool inspection
● Ensure that there is no cartridge strip in the tool. If
there is a cartridge strip in the tool, remove it by hand
from the tool.
● Check all external parts of the tool for damage at reg-
ular intervals and check that all controls operate prop-
erly. Do not operate the tool when parts are damaged or
when the controls do not operate properly. If necessary,
have the tool repaired at a Hilti service centre.
● Check the buffer and piston for wear (see "8. Care
and maintenance").
6
Printed: 12.08.2013 | Doc-Nr: PUB / 5069839 / 000 / 02
All manuals and user guides at all-guides.com
3.85 Kg (8.49 lb)
478 mm (18.8")
700 per hour
6.8/11 M (27 cal. short) green, yellow, red, black
4 cartridge power levels, regulation wheel with locking
function
6.2 Choosing the right fastener guide / piston / fas-
tener combination
Use of the wrong combination may present a risk of
injury. Damage to the tool may also result or fastening
quality may be negatively affected.