7. Fill the cupinlet (4) approximately half-full with clea-
ning fluid (warm water or appropriate solvent).
8. Remove and clean material strainer (3) by flushing
with cleaning fluid. Re-install material strainer (3).
9. Install cover (2) and ring (1) onto cup (5).
10. Cover cup fitting (2a) with a rag, shake the entire Cup-
System for a minimum of ten seconds.
Original instruction
11. Wipe clean and dry all components of Cup-System.
Properly dispose of cleaning fluid.

Cleaning the gun

NOTICE:
Strong solvents, such as lacquer thinner, can damage
parts of the gun. Do NOT immerse parts of the gun in sol-
vent.
1. Remove retaining ring and air cap.
2. Trigger the gun and remove fluid nozzle from gun.
NOTICE:
Trigger the gun whenever removing or installing the fluid
nozzle. This prevents the fluid nozzle and needle seating
surfaces from being damaged.
NOTE:
The Gun contain a air cap guide and spring held in place
by fluid nozzle. Upon removal of fluid nozzle, set aside air
cap guide and spring.