SAFETY WARNINGS

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE REGULATIONS
IN FORCE AND ONLY USED IN AN ADEQUATELY VENTILATED AREA. ALWAYS READ
THE INSTRUCTIONS PROVIDED THOROUGHLY BEFORE INSTALLING AND USING
THIS APPLIANCE. THIS APPLIANCE MUST BE INSTALLED BY SPECIALISED GAS
SERVICE ENGINEERS.
THIS APPLIANCE IS DESIGNED AND MANUFACTURED FOR COOKING FOOD
ONLY. ANY OTHER USE IS CONSIDERED IMPROPER AND INCORRECT CREATING
HAZARDOUS CONDITIONS. THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR DAMAGE TO THINGS OR INJURIES TO PERSONS CAUSED BY INCORRECT
INSTALLATION AND / OR INCORRECT AND IMPROPER USE.
BEFORE INSTALLING CHECK THAT LOCAL GAS (GAS QUALITY AND PRESSURE)
AND THE APPLIANCE REGULATORS ARE COMPATIBLE WITH THE APPLIANCE.
GAS REGULATING SPECIFICATIONS FOR THIS APPLIANCE ARE PROVIDED ON THE
LABEL AFFIXED TO THE APPLIANCE (OR ON THE SERIAL PLATE).
THIS APPLIANCE IS NOT CONNECTED TO A FUME EXTRACTION FLUE FOR
EXTRACTING PRODUCTS OF COMBUSTION. IT MUST BE INSTALLED AND
CONNECTED CONFORMING TO INSTALLATION REGULATIONS IN FORCE. IT IS OF
UTMOST IMPORTANCE TO RESPECT LEGISLATION REGARDING VENTILATION.

CABINET APERTURE

THE APPLIANCE MUST FITTED AT AN APPROPRIATE AND SAFE DISTANCE FROM
FLAMMABLE MATERIALS.
This oven has a CLASS 3 grading: BUILT-IN APPLIANCE FOR KITCHENS OR WORKTOPS.
MINIMUM ALLOWABLE DISTANCES FROM WALLS (FIG. 1 - PAG. 122):
170 mm
BETWEEN THE TOP EDGE OF THE APPLIANCE AND TOP HORIZONTAL WALL
100 mm
BETWEEN THE SIDE OF THE APPLIANCE AND ADJACENT SIDE WALLS
SIZE OF CABINET APERTURE
Cut-out a hole in the cabinet as illustrated in FIG. 2 - PG. 123 size will depend on appliance model.
The cabinet must be appropriately constructed and aligned horizontally with the worktop and with the unit. The cabinet
aperture must be perfectly squared and aligned.
If there are apertures for cabinet ventilation, prevent flammable materials from entering.

INSTALLING THE FLUE

MODELS FO290TD - FO290TS - FO291TD - FO291TS - FO390TD - FO390TS
FO391TD - FO391TS MUST BE DUCTED TO A ROOF MOUNTED FLUE.
ONLY INSTALL THE TYPE OF DUCTING AND FLUE DESCRIBED IN THESE
INSTRUCTIONS WHICH CAN BE SOURCED AT SMEV OR TRUMA RETAILERS.
BOTH THE DUCTING AND FLUE MUST BE KEPT AT A SAFE DISTANCE FROM
FLAMMABLE MATERIALS.