Sharpening the splitting blade
After longer operating periods, for reduced splitting performance
or slight deformation of the cutting edge, grind the splitting blade
or sharpen it with a fine file (remove burrs).
How do I check the oil level?
1. The
splitting
column
must be in run-in state.
Now remove the dipstick.
2. Clean the dipstick and
the oil seal.
3. Replace the dipstick fully
into the oil reservoir.
4. Now remove the dipstick
again and read off the oil
level.
If the oil level is between the two marking on the oil dipstick,
there is sufficient oil in the reservoir.
If the oil level is below the lower marking, more oil should be
added with the aid of a clean funnel.
upper marking
lower marking
6. Check the oil seal and replace it if it is damaged in any way.
7. Replace the dipstick into the oil reservoir.
When should I change the oil?
The first oil change should be carried out after 50 operating
hours, and then every 500 operating hours.
Two persons are required for this.
Sharpen wedges
Oil dipstick
Changing the oil:
1. The splitting column must be in run-in state.
2. Now remove the dipstick.
3. Place a container under the log splitter to catch the old oil.
The container should have a capacity of at least 10 litres.
4. Screw off the drain plug to allow the oil to flow out.
5. Insert the seal and drain plug again.
6. Pour in the new hydraulic oil (approx. 7 litres) using a clean
funnel.
7. Clean the dipstick and the oil seal.
8. Check the oil seal and replace it if it is damaged in any way.
9. Replace the dipstick.
Dispose of the old oil properly (local oil disposal point). The
old oil must not be poured into the ground or drainage
system, or mixed with other waste.
Hydraulic oil
We recommend the following hydraulic oils for the hydraulic
cylinder:
Shell Tellus T 22
Aral Vitam Gf 22
BP Energol HLP 22
Mobil DTE 11
or equivalent
Do not use any other types of oil. The use of any other type
of oil will adversely affect the operation of the hydraulic
cylinder.
S
t
o
r
a
g
e
S
t
o
r
a
g
e
Before each storage:
− Retract the splitting cross.
− switch off device
− Close the oil cap.
− Pull out mains plug.
Store machines that are not in use in a dry locked place protected
against frost and outside the reach of children and unauthorized
persons.
Before extended storage, please observe the following to
increase the service life of the device and to ensure smooth
operation:
− thoroughly clean the device.
− Check the device for damaged or worn parts.
− lubricate the splitting column regularly or oil it using
environmentally friendly spray oil.
29