32
CM1A
Power Connection
P1
Red Stripe
2
1
10
9
200 mm ± 10
Connect end P1 to the module socket
Connect end P2 to the power supply
The CM1A module comes with the required power
cable for connecting to a standard Eurorack power
supply system. Follow these steps to connect
power to the module. It is easier to make these
connections before the module has been mounted
into a rack case.
1. Turn the power supply or rack case power off
and disconnect the power cable.
2. Insert the 16-pin connector on the power cable
into the socket on the power supply or rack
case. The connector has a tab that will align
with the gap in the socket, so it cannot be
inserted incorrectly. If the power supply does
not have a keyed socket, be sure to orient pin 1
(-12 V) with the red stripe on the cable.
3. Insert the 10-pin connector into the socket
on the back of the module. The connector
has a tab that will align with the socket for
correct orientation.
4. After both ends of the power cable have been
securely attached, you may mount the module
in a case and turn on the power supply.
Installation
The necessary screws are included with the
module for mounting in a Eurorack case.
Connect the power cable before mounting.
Depending on the rack case, there may be a series
of fixed holes spaced 2 HP apart along the length
of the case, or a track that allows individual
threaded plates to slide along the length of the
P2
1
2
HOT USED
15
16
+ 12V
+ 12V
GROUND
GROUND
- 12V
- 12V
case. The free-moving threaded plates allow
precise positioning of the module, but each plate
should be positioned in the approximate relation
to the mounting holes in your module before
attaching the screws.
Hold the module against the Eurorack rails so
that each of the mounting holes are aligned with
a threaded rail or threaded plate. Attach the
screws part way to start, which will allow small
adjustments to the positioning while you get
them all aligned. After the final position has been
established, tighten the screws down.
Conexión Eléctrica
P1
Red Stripe
2
1
10
9
200 mm ± 10
Connect end P1 to the module socket
Connect end P2 to the power supply
El módulo CM1A incluye el cable de alimentación
necesario para la conexión a un sistema de
alimentación Eurorack standard. Siga estos pasos
para conectar la alimentación al módulo. Lo más
cómodo es que realice estas conexiones antes de
que montar el módulo en el bastidor rack.
1. Apague la fuente de alimentación o el sistema
de alimentación del rack y desconecte el cable
de alimentación.
2. Introduzca el conector de 16 puntas del cable
de alimentación en la toma de la fuente de
alimentación o sistema de alimentación del
rack. El conector tiene una pestaña que se
alinea con el hueco de la toma, por lo que no
puede insertarlo de forma incorrecta. Si la
fuente de alimentación no dispusiese de un
conector con muesca, asegúrese de orientar la
punta 1 (-12 V) al filamento rojo del cable.
Quick Start Guide
33
P2
1
2
HOT USED
15
16
+ 12V
+ 12V
GROUND
GROUND
- 12V
- 12V