Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The appliance is not
working
Internal
temperature is not
low enough
The appliance is
leaking water
The appliance is
noisy
Error code
P1
Room probe failure
P2
Evaporator probe failure
6
UA058_ML_A5_v1_20240911.indb 6
UA058_ML_A5_v1_20240911.indb 6
Probable Cause
The unit is not switched on
Plug or lead are damaged
Fuse in the plug has blown
Mains power supply fault
Too much ice on the evaporator
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat
source or air flow to the condenser
is being interrupted
Ambient temperature is too high
Fan Motor Failed
Wrong temperature setting
The appliance is not properly
levelled
The discharge outlet is blocked
Movement of water to the drain is
obstructed
The appliance has not been installed
in a level or stable position
Probable Cause
Solution
Check the unit is plugged in correctly and
switched on
Replace plug or lead
Replace the fuse
Check mains power supply
Defrost the appliance
Clean the Condenser
Check doors are shut and seals are not
damaged
Move the refrigerator to a more suitable
location
Increase ventilation or move appliance to a
cooler position
Consult a qualified Technician
Set the appropriate temperature
Adjust the screw feet to level the appliance
Clear the discharge outlet
Clear the floor of the appliance (if
applicable)
Check installation position and change if
necessary
Solution
Check probe connections before replacement