Turn On
1. Close the door(s) of the appliance.
2. Switch on the Power Switch [I]. The current temperature within the appliance is displayed.
3. Turn the light switch On [I] or Off [O] as desired.
Set the Operating Temperature
1. Hold the SET button for 3 seconds. The value of the current set point will be displayed.
2. Press the
or
3. Press the SET button to store the temperature.
Manual Defrost
Press and hold the defrost button "aux" for 2 seconds to begin a manual defrost. The defrost light
illuminates.
The defrost cycle will end automatically.
Refrigerating tips:
Condensation and ice will form with frequent and prolonged opening of the doors.
Operating outside of the recommend temperature range and placing next to a heat source will also
increase the amount of ice and internal/external condensation. If external condensation occurs wipe
the surface down with a cloth.
Excessive ice will result in longer running times that will increase energy consumption and increase
the deterioration of components.
If the gasket or seal is damaged or deformed, energy consumption will increase. To restore efficiency,
replace gasket.
Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning.
Empty the appliance and transfer remaining stuff into a freezer.
Clean the interior of the appliance as often as possible.
Do not use abrasive cleaning agents. These can leave harmful residues.
Always wipe dry after cleaning.
The appliance should be switched off when not in use.
Carry out a manual defrost if excessive ice is present.
Remove any water that may be present before usage.
Cleaning the Condenser
The condenser is part of the refrigeration system.
The condenser requires monthly cleaning.
Always disconnect power supply before carrying out
Routine Maintenance.
Failure to clean the condenser will increase energy
consumption, reduce the performance and life of your
Polar unit, and thus may invalidate your warranty.
These models have a removable filter which can be
cleaned with a vacuum cleaner. To access the filter,
open the magnetic back panel first.